Receiving
Rhodimet AT 88 is delivered in three different forms of packaging.
For feed mills with a large consumption, Rhodimet AT 88 is
usually delivered by tank trucks. Customers who use less Rhodimet
AT 88 may prefer international bulk container (1150 kg) or drums
(250 kg).
If Rhodimet AT 88 is delivered by tanker, storage systems
with a tank are obligatory. These tanks must have all technical
elements which are necessary not only for discharging the tankers
but also for the transfer and the dosing of Rhodimet AT 88
into the feed. The quick coupling valve, the receiving line to the
tank inlet and the check valve should have a diameter of 80 mm.
Storage
Rhodimet AT 88 should be stored in a tank with the following
features :
- A hopper bottom (on stand) or a flat bottom
- Capacity of 20 m3 minimum, and a maximum depending on the specific
consumption, taking into account the space which is available for
the tank
- Made of polyethylene (HD) or reinforced polyester with an anti-acid
coating
- Manhole, external discharge vent, high level, float gauge or ultrasonic
probe
- Insulation (depending on weather conditions) such as glass wool
insulation covering the entire tank
- Hot water heating loop at the bottom of the tank (To limit corrosion,
the loop should not come in contact with the product)
- Recommended storage temperature of 20°C
|