Rhodimet™ AT 88 - Receiving / Storage

Receiving
Rhodimet™ AT 88 is delivered in three different forms of packaging. For feed mills with a large consumption, Rhodimet™ AT 88 is usually delivered by tank trucks. Customers who use less Rhodimet™ AT 88 may prefer international bulk container (1150 kg) or drums (250 kg).

If Rhodimet™ AT 88 is delivered by tanker, storage systems with a tank are obligatory. These tanks must have all technical elements which are necessary not only for discharging the tankers but also for the transfer and the dosing of Rhodimet™ AT 88 into the feed. The quick coupling valve, the receiving line to the tank inlet and the check valve should have a diameter of 80 mm.


Storage
Rhodimet™ AT 88 should be stored in a tank with the following features :
- A hopper bottom (on stand) or a flat bottom
- Capacity of 20 m3 minimum, and a maximum depending on the specific consumption, taking into account the space which is available for the tank
- Made of polyethylene (HD) or reinforced polyester with an anti-acid coating
- Manhole, external discharge vent, high level, float gauge or ultrasonic probe
- Insulation (depending on weather conditions) such as glass wool insulation covering the entire tank
- Hot water heating loop at the bottom of the tank (To limit corrosion, the loop should not come in contact with the product)
- Recommended storage temperature of 20°C